Lovibond COD Vario Tube Test 0–150 mg/L
The Lovibond COD Vario Tube Test 0–150 mg/L is a ready-to-use sealed tube reagent designed for the photometric determination of Chemical Oxygen Demand (COD) in water and wastewater samples. This product is the Low Range (LR) COD Vario tube test and is suitable for samples with COD concentrations from 0 to 150 mg/L.
Lovibond COD Vario tube tests use the dichromate method and are designed for use with compatible Lovibond photometers. The 0–150 mg/L range is particularly useful for water and wastewater samples where COD concentrations are relatively low and accurate measurement within the lower range is required.
Key Features
- Brand: Lovibond
- Product Type: COD Vario Tube Test
- Measurement Range: 0–150 mg/L
- Range: Low Range (LR)
- Tube Diameter: 16 mm
- Standard Pack: 25 Tests
- Method: Dichromate/H₂SO₄
- Application: Chemical Oxygen Demand testing
- Suitable For: Water and wastewater analysis
- Tube Format: Sealed reaction tube
- Measurement Method: Photometric analysis
The Lovibond COD Vario range is available in different measurement ranges, allowing laboratories and water-testing professionals to select a suitable test according to the expected COD concentration of their samples.
What is COD?
Chemical Oxygen Demand (COD) is a commonly used water-quality parameter that indicates the amount of oxygen required to chemically oxidize oxidizable substances present in a water sample.
COD testing is widely used in water treatment, wastewater monitoring, environmental analysis, industrial laboratories, and research facilities. Measuring COD helps laboratories assess the level of chemically oxidizable substances in water and wastewater.
The Lovibond COD Vario system determines COD through a digestion process followed by photometric measurement using a compatible photometer.
How the Lovibond COD Vario 0–150 mg/L Test Works
The Lovibond COD Vario tube test uses a sealed reaction tube containing the required reagents for the COD determination. A measured quantity of the water sample is added to the appropriate reaction tube according to the manufacturer’s test procedure.
The prepared tube is then securely closed and mixed carefully. The sample undergoes a controlled digestion process in a suitable thermoreactor. During digestion, oxidizable substances in the sample react with the chemical reagents.
After digestion, the reaction tube is allowed to cool before photometric measurement. The processed tube is then placed into a compatible Lovibond photometer, where the COD concentration is determined based on the photometric reaction.
Because COD testing involves chemical reagents and elevated temperatures during digestion, appropriate laboratory safety procedures, protective equipment, and manufacturer’s instructions should always be followed.

Applications
The Lovibond COD Vario Tube Test 0–150 mg/L is suitable for:
- Water Quality Testing
- Wastewater Testing
- Environmental Water Monitoring
- Laboratory Water Analysis
- Industrial Process Water Testing
- Wastewater Treatment Monitoring
- Research and Analytical Laboratories
- Municipal Water Treatment Applications
- Environmental Monitoring Programs
The low-range format is particularly useful when the expected COD concentration of the sample falls within the 0–150 mg/L measurement range.
Compatibility
The 0–150 mg/L COD Vario tube test is designed for use with compatible Lovibond photometers that support the corresponding COD Vario method.
Before purchasing or using the tubes, users should confirm compatibility with their specific photometer and thermoreactor. Following the manufacturer’s recommended procedure helps ensure reliable and repeatable COD measurements.
Lovibond COD Vario Tube Test 0–150 mg/L Price in Bangladesh
Looking for the Lovibond COD Vario Tube Test 0–150 mg/L price in Bangladesh? Contact M/S Bright Scientific Co. for the latest price, availability, and bulk-order quotation.
Frequently Asked Questions (FAQ)
1. What is the measurement range of this COD Vario tube test?
The measurement range is 0–150 mg/L, making it suitable for low-range COD testing.
2. What type of COD test is this?
It is the Low Range (LR) Lovibond COD Vario tube test.
3. How many tests are included in one pack?
The standard pack contains 25 tests.
4. What method is used for COD determination?
The test uses the dichromate/H₂SO₄ method followed by photometric measurement.
5. What samples can be tested?
It is suitable for appropriate water and wastewater samples with expected COD concentrations within the 0–150 mg/L range.
6. Is this suitable for high-COD wastewater?
This test is intended for the 0–150 mg/L low range. Samples expected to contain higher COD concentrations should be tested using a suitable higher-range COD tube test.
7. Can this COD tube test be used with a Lovibond photometer?
Yes. It is designed for use with compatible Lovibond photometer systems supporting the corresponding COD Vario method.
8. Why is COD testing important?
COD testing provides an important measurement for evaluating water and wastewater quality and monitoring chemically oxidizable substances in a sample.
Lovibond COD Vario Tube Test 0–150 mg/L in Bangladesh
M/S Bright Scientific Co. supplies laboratory testing products and water-quality analysis solutions in Bangladesh. For the Lovibond COD Vario Tube Test 0–150 mg/L, contact Bright Scientific for current pricing, availability, and quotation requirements.







Reviews
There are no reviews yet.