Product Description: Specific Gravity Glass Hydrometer 1.400–1.500
The Specific Gravity Glass Hydrometer 1.400–1.500 is a precision measuring instrument designed to measure the specific gravity or relative density of liquids within the 1.400 to 1.500 range. Made from glass, this hydrometer provides a simple and convenient method for measuring liquid density without requiring electronic power or complicated measuring equipment. It can be suitable for laboratory testing, industrial applications, quality control, educational demonstrations, and routine liquid analysis where the sample falls within the specified measurement range.
Key Specifications
- Product Name: Specific Gravity Glass Hydrometer
- Instrument Type: Glass Hydrometer
- Measurement Parameter: Specific Gravity / Relative Density
- Measurement Range: 1.400–1.500
- Material: Glass
- Measurement Method: Buoyancy and graduated scale reading
- Application: Laboratory, Industrial, Educational, and Quality Control Use
- Operation: Manual Measurement
- Power Requirement: No Electrical Power Required
- Handling: Handle carefully to prevent breakage
Note: Graduation interval, calibration temperature, accuracy, and scale length should be confirmed from the specific product supplied.
Key Features
Specific Gravity Measurement
The hydrometer is designed for measuring the specific gravity or relative density of liquids within the 1.400–1.500 measurement range.
Glass Construction
Its glass construction allows the user to observe the instrument and liquid level clearly while taking a reading. Because glass can break if dropped or handled improperly, careful handling is recommended.
Simple Manual Operation
The instrument operates through the natural principle of buoyancy. It does not require batteries, electricity, or an electronic display, making it convenient for routine measurements.
Defined Measurement Range
The 1.400–1.500 range is suitable for liquid samples whose expected specific gravity falls within this interval. Choosing the appropriate range is important for practical and meaningful measurements.
Suitable for Routine Testing
The hydrometer can be used as part of routine laboratory testing, quality-control procedures, educational demonstrations, and suitable industrial liquid analysis.
Typical Applications
The Specific Gravity Glass Hydrometer 1.400–1.500 can be used in laboratories, educational institutions, industrial facilities, research environments, and quality-control departments where relative density measurements are required.
Typical applications may include:
- Laboratory liquid density testing
- Specific gravity measurement
- Industrial liquid quality control
- Chemical solution analysis
- Educational demonstrations of density and buoyancy
- Routine liquid testing
- Process monitoring where appropriate
- Comparative analysis of liquid density
The suitability of the hydrometer depends on the type of liquid, expected specific gravity, calibration conditions, and required measurement accuracy.
How to Use a Specific Gravity Glass Hydrometer
- Select a clean measuring cylinder that is tall enough for the hydrometer to float freely.
- Fill the cylinder with the liquid sample, leaving enough space for the hydrometer.
- Avoid excessive bubbles in the sample because they may affect the floating position.
- Gently lower the hydrometer into the liquid.
- Allow the hydrometer to float freely without touching the sides or bottom of the cylinder.
- Wait until the hydrometer becomes stable.
- Read the graduated scale at the appropriate liquid level according to the manufacturer’s instructions.
- Record the specific gravity value.
- Remove and clean the hydrometer appropriately after testing.
Always check the specified calibration temperature because temperature differences can affect liquid density and the resulting hydrometer reading.

Frequently Asked Questions (FAQ)
Q1: What is a Specific Gravity Glass Hydrometer 1.400–1.500 used for?
It is used to measure the specific gravity or relative density of suitable liquid samples that fall within the 1.400–1.500 measurement range.
Q2: What does the 1.400–1.500 range mean?
The range indicates the specific gravity values that the hydrometer is designed to measure, from 1.400 to 1.500.
Q3: How does a glass hydrometer work?
A hydrometer works on the principle of buoyancy. It floats at a particular level in a liquid depending on the liquid’s density, and the value is read from its graduated scale.
Q4: Does this hydrometer require electricity or batteries?
No. It is a manually operated glass instrument and does not require batteries or an electrical power supply.
Q5: Can this hydrometer measure liquids outside the 1.400–1.500 range?
The instrument is intended for liquids whose specific gravity falls within its specified range. A different hydrometer range may be required for samples outside this interval.
Q6: How can I get a more reliable reading?
Allow the hydrometer to float freely without touching the cylinder, minimize bubbles, use a clean measuring cylinder, and take the reading according to the manufacturer’s instructions and specified calibration temperature.
Q7: Is the hydrometer reusable?
Yes, a glass hydrometer can generally be used repeatedly when it is properly handled, cleaned, and maintained.
Q8: What type of container should be used with the hydrometer?
A clean, tall measuring cylinder or suitable container that allows the hydrometer to float freely without touching the sides or bottom is recommended.
Q9: Where can this hydrometer be used?
It can be suitable for laboratories, industrial facilities, educational institutions, research environments, and quality-control applications requiring specific gravity measurements.
Q10: Does temperature affect hydrometer readings?
Yes. Liquid density can change with temperature, so the specified calibration temperature should be considered when taking and interpreting measurements.
Where to Buy Specific Gravity Glass Hydrometer 1.400–1.500
The Specific Gravity Glass Hydrometer 1.400–1.500 is available from M/S Bright Scientific Co., a supplier of laboratory equipment, scientific instruments, and laboratory products in Bangladesh.
Contact:
M/S Bright Scientific Co.
Phone: +880 1711285976




Reviews
There are no reviews yet.