Water Hardness Test Kit HI3812 – Hanna Instruments
The Water Hardness Test Kit HI3812 by Hanna Instruments is a titration-based chemical test kit designed to measure total water hardness as CaCO₃ (calcium carbonate). It uses the EDTA titration method and provides two measurement ranges, making it suitable for testing samples with different hardness levels. The kit is supplied with the necessary reagents and accessories to perform approximately 100 tests.
Total Water Hardness Testing
Water hardness is primarily associated with the presence of calcium and magnesium ions in water. Other ions, including iron, zinc, and manganese, can also contribute to overall hardness. Monitoring hardness is important because excessive hardness can contribute to scale formation and clogging in water pipes and water-handling systems.
The HI3812 provides a practical manual titration procedure for determining total hardness. The test uses a hardness buffer and Calmagite indicator, followed by titration with an EDTA solution. The endpoint is identified by a color change, allowing the user to determine the hardness concentration from the amount of titrant used.
Measurement Ranges
The HI3812 offers two ranges for total hardness:
- 0.0–30.0 mg/L (ppm) CaCO₃
- 0–300 mg/L (ppm) CaCO₃
The smallest increments are 0.3 mg/L for the 0.0–30.0 mg/L range and 3 mg/L for the 0–300 mg/L range. For lower hardness concentrations, the larger sample volume procedure can be used to improve precision.
EDTA Titration Method
The HI3812 uses an EDTA titration method. During the test, the water sample is first buffered to approximately pH 10. Calmagite indicator reacts with calcium and magnesium ions to produce a colored complex. EDTA is then added as the titrant. When the metal ions have been complexed by EDTA, the indicator changes color, providing the titration endpoint. The amount of EDTA used is then used to calculate total hardness as mg/L CaCO₃.
Complete Testing Kit
The HI3812 comes with the materials required to perform the test, including:
- Hardness Buffer – 30 mL
- Calmagite Indicator – 10 mL
- HI3812-0 EDTA Solution – 120 mL
- 20 mL plastic beaker with cap
- 50 mL plastic beaker with cap
- 1 mL syringe with tip
The manufacturer specifies an average capacity of approximately 100 tests. Replacement reagents are also available separately as HI3812-100, so the complete kit does not need to be replaced when the supplied reagents are exhausted.

Applications
The Water Hardness Test Kit HI3812 can be used for total hardness testing in various laboratory and water-quality applications, including:
- Water quality analysis
- Laboratory water testing
- Environmental water testing
- Water treatment monitoring
- Industrial water testing
- Educational and research laboratories
- Monitoring calcium and magnesium-related hardness
Its manual titration format makes it suitable for users who require a straightforward chemical method for determining total water hardness.
Technical Specifications
Brand: Hanna Instruments
Product: Water Hardness Test Kit
Test Parameter: Total Hardness
Measurement Type: Titration
Method: EDTA
Range: 0.0–30.0 mg/L and 0–300 mg/L CaCO₃
Smallest Increment: 0.3 mg/L and 3 mg/L
Sample Size: 5 mL or 50 mL
Number of Tests: Approximately 100
Dimensions: 200 × 120 × 60 mm
Weight: Approximately 460 g
FAQ
1. What does the HI3812 measure?
The HI3812 measures total water hardness expressed as CaCO₃.
2. What method does the HI3812 use?
It uses an EDTA titration method with a Calmagite indicator.
3. What is the measurement range?
The kit has two ranges: 0.0–30.0 mg/L and 0–300 mg/L CaCO₃.
4. How many tests can be performed?
The supplied reagents are sufficient for approximately 100 tests.
5. What does water hardness indicate?
Water hardness mainly indicates the concentration of calcium and magnesium ions in water.
6. Can replacement reagents be purchased?
Yes. Hanna offers HI3812-100 replacement reagents, with approximately 100 tests.
7. What sample sizes are used?
The procedure uses either a 5 mL or 50 mL sample, depending on the measurement range and desired precision.
8. Who can use this test kit?
It can be used in laboratories, water-treatment applications, environmental testing, research, education, and industrial water-quality monitoring.Water Hardness Test Kit
9. What is the smallest increment?
The smallest increment is 0.3 mg/L in the low range and 3 mg/L in the high range.Water Hardness Test Kit
10. Is the kit supplied with the necessary accessories?
Yes. The kit includes the required reagents, beakers, syringe, and other accessories needed for the test.





Reviews